{"id":278262,"date":"2022-11-02T13:25:04","date_gmt":"2022-11-02T13:25:04","guid":{"rendered":"https:\/\/www.sanier.pl\/bw-hasla\/08-studio-hydroizolacji-sanier-bledy-przy-projektowaniu\/"},"modified":"2025-02-20T08:22:51","modified_gmt":"2025-02-20T08:22:51","slug":"08-studio-hydroizolacji-sanier-bledy-przy-projektowaniu","status":"publish","type":"knowledgebase","link":"https:\/\/www.sanier.pl\/en\/bw-hasla\/08-studio-hydroizolacji-sanier-bledy-przy-projektowaniu\/","title":{"rendered":"Design Mistakes"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<h1 data-start=\"0\" data-end=\"25\"><strong data-start=\"4\" data-end=\"23\">Design Mistakes<\/strong><\/h1>\n<h2 data-start=\"27\" data-end=\"99\"><strong data-start=\"27\" data-end=\"97\">Hydrostop expert Marek Mularczyk discusses common design mistakes.<\/strong><\/h2>\n<p data-start=\"101\" data-end=\"174\">Are you considering waterproofing but unsure which materials to choose?<\/p>\n<p data-start=\"176\" data-end=\"333\">Together with <strong data-start=\"190\" data-end=\"226\">Hydrostop expert Marek Mularczyk<\/strong>, we have prepared a short series dedicated to waterproofing. Here, you\u2019ll find answers to key questions:<\/p>\n<ul data-start=\"335\" data-end=\"448\" data-is-last-node=\"\">\n<li data-start=\"335\" data-end=\"365\"><strong data-start=\"337\" data-end=\"363\">What is waterproofing?<\/strong><\/li>\n<li data-start=\"366\" data-end=\"403\"><strong data-start=\"368\" data-end=\"401\">How is waterproofing applied?<\/strong><\/li>\n<li data-start=\"404\" data-end=\"448\" data-is-last-node=\"\"><strong data-start=\"406\" data-end=\"448\" data-is-last-node=\"\">Is foundation waterproofing necessary?<\/strong><\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_video link=\"https:\/\/www.youtube.com\/watch?v=jB0K1q-LLBQ\"][vc_empty_space][vc_column_text]<\/p>\n<h3 data-start=\"367\" data-end=\"400\"><strong data-start=\"372\" data-end=\"398\">Common Design Mistakes<\/strong><\/h3>\n<p data-start=\"402\" data-end=\"606\">Unfortunately, there are many potential mistakes that can be made during the design phase. One of the first challenges arises when determining the <strong data-start=\"549\" data-end=\"603\">number of construction joints and expansion joints<\/strong>.<\/p>\n<ul data-start=\"608\" data-end=\"839\">\n<li data-start=\"608\" data-end=\"705\">The <strong data-start=\"614\" data-end=\"626\">designer<\/strong> often prefers <strong data-start=\"641\" data-end=\"649\">more<\/strong> construction joints to ensure proper concrete curing.<\/li>\n<li data-start=\"706\" data-end=\"839\">The <strong data-start=\"712\" data-end=\"726\">contractor<\/strong>, on the other hand, aims for <strong data-start=\"756\" data-end=\"765\">fewer<\/strong> joints to pour as large an area of concrete as possible in a single go.<\/li>\n<\/ul>\n<p data-start=\"841\" data-end=\"1239\">Another commonly overlooked aspect is <strong data-start=\"879\" data-end=\"908\">the design of entry ramps<\/strong>\u2014whether they should be <strong data-start=\"932\" data-end=\"959\">placed on a shared slab<\/strong> or <strong data-start=\"963\" data-end=\"998\">separated by an expansion joint<\/strong>. These decisions should ideally be addressed <strong data-start=\"1044\" data-end=\"1071\">during the design phase<\/strong> to prevent issues later. On-site, it may turn out that <strong data-start=\"1127\" data-end=\"1147\">expansion dowels<\/strong> are needed to <strong data-start=\"1162\" data-end=\"1192\">prevent joint displacement<\/strong> on a slope leading to an underground garage.<\/p>\n<h4 data-start=\"1241\" data-end=\"1273\"><strong data-start=\"1246\" data-end=\"1271\">Consult Experts Early<\/strong><\/h4>\n<p data-start=\"1275\" data-end=\"1371\">To avoid such issues, it's best to <strong data-start=\"1310\" data-end=\"1347\">consult experienced professionals<\/strong> early in the process.<\/p>\n<p data-start=\"1373\" data-end=\"1707\"><strong data-start=\"1376\" data-end=\"1394\">Important Tip!<\/strong><br data-start=\"1394\" data-end=\"1397\" \/>When searching for specialists, rely on <strong data-start=\"1437\" data-end=\"1469\">local building supply stores<\/strong> rather than large online portals or magazines, where many articles are <strong data-start=\"1541\" data-end=\"1554\">sponsored<\/strong> and overly positive. <strong data-start=\"1576\" data-end=\"1598\">Local distributors<\/strong> often have <strong data-start=\"1610\" data-end=\"1634\">first-hand knowledge<\/strong> of skilled professionals and can provide <strong data-start=\"1676\" data-end=\"1704\">valuable recommendations<\/strong>.<\/p>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<h5 data-start=\"0\" data-end=\"49\"><strong data-start=\"4\" data-end=\"47\">Want to Learn More About Waterproofing?<\/strong><\/h5>\n<h5 data-start=\"51\" data-end=\"85\">Read our guides \u2192 <a href=\"https:\/\/www.sanier.pl\/poradniki\/\"><strong data-start=\"69\" data-end=\"83\">CLICK HERE<\/strong><\/a><\/h5>\n<h5 data-start=\"87\" data-end=\"193\">If you have any additional questions about waterproofing, contact our specialist at <strong data-start=\"171\" data-end=\"192\">(+48) 533 343 595<\/strong>.<\/h5>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column width=\"1\/3\"][vc_hoverbox image=\"245111\" primary_title=\"\" hover_title=\"Hydrostop mix 203\" hover_btn_title=\"Buy\" hover_btn_color=\"sky\" hover_add_button=\"true\" hover_btn_link=\"url:https%3A%2F%2Fwww.sanier.pl%2Fprodukt%2Fhydrostop-203%2F|title:Hydrostop%20203\"][\/vc_hoverbox][\/vc_column][vc_column width=\"1\/3\"][vc_hoverbox image=\"245110\" primary_title=\"\" hover_title=\"Hydrostop mix 209\" hover_btn_title=\"Buy\" hover_btn_color=\"sky\" hover_add_button=\"true\" hover_btn_link=\"url:https%3A%2F%2Fwww.sanier.pl%2Fprodukt%2Fhydrostop-209%2F|title:Hydrostop%20209\"][\/vc_hoverbox][\/vc_column][vc_column width=\"1\/3\"][vc_hoverbox image=\"245109\" primary_title=\"\" hover_title=\"Hydrostop mix 401\" hover_btn_title=\"Buy\" hover_btn_color=\"sky\" hover_add_button=\"true\" hover_btn_link=\"url:https%3A%2F%2Fwww.sanier.pl%2Fprodukt%2Fhydrostop-401%2F|title:Hydrostop%20401\"][\/vc_hoverbox][\/vc_column][\/vc_row][vc_column width=\"1\/3\"][\/vc_column][vc_row][vc_column][vc_empty_space][vc_column_text]<\/p>\n<h4><a href=\"https:\/\/hydrostop.pl\/91-technologia---zasada-penetracji-materialow-hydrostop\" target=\"_blank\" rel=\"noopener\">HYDROSTOP Technology<\/a><\/h4>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":55,"featured_media":0,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","categories":[873],"tags":[],"class_list":["post-278262","knowledgebase","type-knowledgebase","status-publish","hentry","category-knowledge-base"],"_links":{"self":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase\/278262","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/users\/55"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/comments?post=278262"}],"version-history":[{"count":0,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase\/278262\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/media?parent=278262"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/categories?post=278262"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/tags?post=278262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}