{"id":278152,"date":"2022-05-20T12:13:25","date_gmt":"2022-05-20T12:13:25","guid":{"rendered":"https:\/\/www.sanier.pl\/bw-hasla\/abc-warunkow-ogolnych-stawianych-podlozu\/"},"modified":"2025-02-13T14:00:51","modified_gmt":"2025-02-13T14:00:51","slug":"abc-warunkow-ogolnych-stawianych-podlozu","status":"publish","type":"knowledgebase","link":"https:\/\/www.sanier.pl\/en\/bw-hasla\/abc-warunkow-ogolnych-stawianych-podlozu\/","title":{"rendered":"ABC of General Conditions Required for the Substrate"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<h2><\/h2>\n<h2 style=\"text-align: center;\" data-start=\"0\" data-end=\"62\"><strong data-start=\"4\" data-end=\"60\">ABC of General Conditions Required for the Substrate<\/strong><\/h2>\n<p data-start=\"64\" data-end=\"258\">When planning to build a house, it is essential to understand the requirements that the <strong data-start=\"152\" data-end=\"165\">substrate<\/strong> must meet, particularly to ensure the correct technical <strong data-start=\"222\" data-end=\"255\">installation of waterproofing<\/strong>.<\/p>\n<p data-start=\"260\" data-end=\"442\">This is <strong data-start=\"268\" data-end=\"285\">not the first<\/strong> thing that comes to mind when preparing for construction, but <strong data-start=\"348\" data-end=\"377\">poorly prepared substrate<\/strong> is one of the most common reasons why <strong data-start=\"416\" data-end=\"439\">waterproofing fails<\/strong>.<\/p>\n<h3 data-start=\"444\" data-end=\"485\"><strong data-start=\"448\" data-end=\"483\">Requirements for the Substrate:<\/strong><\/h3>\n<ol data-start=\"487\" data-end=\"2262\">\n<li data-start=\"487\" data-end=\"1053\">\n<p data-start=\"490\" data-end=\"1053\"><strong data-start=\"490\" data-end=\"533\">Dimensional Tolerances of the Substrate<\/strong><br data-start=\"533\" data-end=\"536\" \/>a) Newly constructed walls\/structures must meet the dimensional tolerances permitted by <strong data-start=\"627\" data-end=\"664\">ITB (Building Research Institute)<\/strong>.<br data-start=\"665\" data-end=\"668\" \/>b) Existing walls\/structures do not have to comply with dimensional tolerance requirements.<br data-start=\"762\" data-end=\"765\" \/>c) <strong data-start=\"771\" data-end=\"799\">Tank-type waterproofing:<\/strong> The sealing layer is applied directly to the <strong data-start=\"845\" data-end=\"867\">structural element<\/strong>.<br data-start=\"868\" data-end=\"871\" \/>d) <strong data-start=\"877\" data-end=\"901\">Ground-level floors:<\/strong> The substrate should be prepared to meet the required <strong data-start=\"956\" data-end=\"981\">dimensional standards<\/strong> (ITB, DIN 18202, or Merkblatt \u201cTolerances in Building Construction\u201d).<\/p>\n<\/li>\n<li data-start=\"1055\" data-end=\"1204\">\n<p data-start=\"1058\" data-end=\"1204\">The substrate is usually <strong data-start=\"1083\" data-end=\"1104\">moist or even wet<\/strong> \u2013 <strong data-start=\"1107\" data-end=\"1176\">most modern waterproofing materials tolerate a matte-damp surface<\/strong> (without standing water).<\/p>\n<\/li>\n<li data-start=\"1206\" data-end=\"1307\">\n<p data-start=\"1209\" data-end=\"1307\">A <strong data-start=\"1211\" data-end=\"1237\">highly water-saturated<\/strong> substrate can be <strong data-start=\"1255\" data-end=\"1269\">pre-sealed<\/strong> using <strong data-start=\"1276\" data-end=\"1304\">mineral sealing slurries<\/strong>.<\/p>\n<\/li>\n<li data-start=\"1309\" data-end=\"1382\">\n<p data-start=\"1312\" data-end=\"1382\">The substrate <strong data-start=\"1326\" data-end=\"1361\">must be stable and load-bearing<\/strong>, free from cracks.<\/p>\n<\/li>\n<li data-start=\"1384\" data-end=\"1687\">\n<p data-start=\"1387\" data-end=\"1687\"><strong data-start=\"1387\" data-end=\"1420\">Exposed or excavated elements<\/strong> must be <strong data-start=\"1429\" data-end=\"1465\">thoroughly cleaned and inspected<\/strong> \u2013 remove <strong data-start=\"1475\" data-end=\"1502\">loose masonry fragments<\/strong>, crumbling mortar, and <strong data-start=\"1526\" data-end=\"1561\">any material affecting adhesion<\/strong>. Strongly <strong data-start=\"1572\" data-end=\"1599\">salt-contaminated walls<\/strong> should be mechanically cleaned, and <strong data-start=\"1636\" data-end=\"1663\">desalination treatments<\/strong> should be considered.<\/p>\n<\/li>\n<li data-start=\"1689\" data-end=\"1789\">\n<p data-start=\"1692\" data-end=\"1789\"><strong data-start=\"1692\" data-end=\"1729\">Gravel nests, cavities, and voids<\/strong> must be filled with <strong data-start=\"1750\" data-end=\"1786\">system-compatible repair mortars<\/strong>.<\/p>\n<\/li>\n<li data-start=\"1791\" data-end=\"1941\">\n<p data-start=\"1794\" data-end=\"1941\"><strong data-start=\"1794\" data-end=\"1851\">External foundation edges should be rounded or milled<\/strong>. Internal corners should have a <strong data-start=\"1884\" data-end=\"1901\">cove (fillet)<\/strong> made with <strong data-start=\"1912\" data-end=\"1938\">system-specific mortar<\/strong>.<\/p>\n<\/li>\n<li data-start=\"1943\" data-end=\"2064\">\n<p data-start=\"1946\" data-end=\"2064\"><strong data-start=\"1946\" data-end=\"1979\">A pressure distribution layer<\/strong> should be applied on <strong data-start=\"2001\" data-end=\"2024\">horizontal surfaces<\/strong> sealed with <strong data-start=\"2037\" data-end=\"2061\">bituminous materials<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2066\" data-end=\"2175\">\n<p data-start=\"2069\" data-end=\"2175\"><strong data-start=\"2069\" data-end=\"2100\">Coating-based waterproofing<\/strong> must be applied directly <strong data-start=\"2126\" data-end=\"2156\">to the structural elements<\/strong> of the building.<\/p>\n<\/li>\n<li data-start=\"2177\" data-end=\"2262\">\n<p data-start=\"2181\" data-end=\"2262\"><strong data-start=\"2181\" data-end=\"2220\">Seal point and linear water inflows<\/strong> before applying waterproofing coatings.<\/p>\n<\/li>\n<\/ol>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center;\" data-start=\"2271\" data-end=\"2326\"><strong data-start=\"2275\" data-end=\"2324\">Wondering How to Waterproof Your Foundations?<\/strong><\/h3>\n<p style=\"text-align: center;\" data-start=\"2327\" data-end=\"2382\">All the details can be found in our <strong data-start=\"2363\" data-end=\"2380\">expert guide!<\/strong><\/p>\n<p style=\"text-align: center;\" data-start=\"2384\" data-end=\"2405\"><a href=\"https:\/\/www.sanier.pl\/poradniki_sanier\/hydroizolacja-poradnik-cz1\/\">\u00a0<strong data-start=\"2387\" data-end=\"2403\">CHECK IT OUT<\/strong><\/a><\/p>\n<h3 style=\"text-align: center;\"><\/h3>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<h3><strong data-start=\"2416\" data-end=\"2447\">Do You Have More Questions?<\/strong><\/h3>\n<p data-start=\"2450\" data-end=\"2527\">We are happy to assist you with <strong data-start=\"2482\" data-end=\"2524\">waterproofing and renovation solutions<\/strong>.<\/p>\n<p data-start=\"2529\" data-end=\"2722\">Our team of <strong data-start=\"2541\" data-end=\"2556\">specialists<\/strong> is ready to help. <strong data-start=\"2575\" data-end=\"2586\">Call us<\/strong> at <strong data-start=\"2590\" data-end=\"2612\">(+48) 12 307 24 98<\/strong>, and we will provide you with a <strong data-start=\"2645\" data-end=\"2719\">tailored waterproofing system and a complete list of required products<\/strong>.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h4><\/h4>\n<h4><strong>Follow us on <a href=\"https:\/\/www.instagram.com\/sanier_pl\/\" target=\"_blank\" rel=\"noopener\">Instagram<\/a> and <a href=\"https:\/\/www.facebook.com\/sanierpl\" target=\"_blank\" rel=\"noopener\">Facebook<\/a> for updates on hydro-insulation solutions, renovation tips, and promotions!<\/strong><\/h4>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"author":55,"featured_media":271166,"menu_order":0,"comment_status":"open","ping_status":"closed","template":"","categories":[873],"tags":[],"class_list":["post-278152","knowledgebase","type-knowledgebase","status-publish","has-post-thumbnail","hentry","category-knowledge-base"],"_links":{"self":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase\/278152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase"}],"about":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/types\/knowledgebase"}],"author":[{"embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/users\/55"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/comments?post=278152"}],"version-history":[{"count":0,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/knowledgebase\/278152\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/media\/271166"}],"wp:attachment":[{"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/media?parent=278152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/categories?post=278152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sanier.pl\/en\/wp-json\/wp\/v2\/tags?post=278152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}